Validation des modalités d’imagerie CBCT basse dose dans les bilans de localisation des canines incluses


Thèse ou mémoire / Thesis or Dissertation
Loading...
Thumbnail Image

Contributor(s)

Published in

Conference Date

Conference Place

Publisher

Degree Level

Maîtrise / Master's

Affiliation

Keywords

  • CBCT
  • Réduction de la dose
  • Reconstruction itérative
  • Canine incluse
  • Orthodontie
  • Dose reduction
  • Iterative reconstruction
  • Impacted canine
  • Orthodontics

Funding organization(s)

Abstract

OBJECTIF : L’objectif de cette étude a été de valider le potentiel des méthodes de reconstruction itérative nouvellement développées en imageries CT à faisceau conique, afin de réduire la dose d’exposition dans le cadre des bilans de localisation des canines incluses. MÉTHODOLOGIE : Quarante examens par imagerie volumétrique à faisceau conique de canines incluses ont été reconstruits à pleine dose (D), demi-dose (D2) et quart de dose (D4). Ces examens ont été analysés par un radiologiste maxillo-facial et par un résident en orthodontie. La cohérence entre les évaluations des critères radiologiques retenus a été évaluée avec les tests de Kappa Cohen. RÉSULTATS : Les résultats de cette étude ont montré de fortes valeurs de Kappa concernant l'évaluation inter-examinateur de la position de la canine impactée avec des scores compris entre 0.606 – 0.839. Les valeurs de Kappa déterminées pour la résorption, l'ankylose et les lésions associées étaient beaucoup plus faibles avec des scores compris entre 0.000 et 0.529. CONCLUSION : Cette étude a permis de montrer que la localisation des canines incluses pourrait potentiellement être possible à faible dose (1/4 dose), comparativement à un dosage conventionnel. Toutefois, le diagnostic de la résorption, de l'ankylose ou encore de certaines lésions associées nécessitent de la haute résolution et donc des acquisitions à pleine dose.


AIM : The aim of this study was to validate the potential of newly developed iterative reconstruction methods in cone beam CT imaging to reduce the exposure dose for localization assessments of impacted canines. METHODS : Forty Cone beam CT examinations of impacted canines were reconstructed at full dose (D), half dose (D2) and quarter dose (D4). These examinations were analyzed by a maxillofacial radiologist and by an orthodontic resident. Consistency between the assessments of the selected radiological criteria was evaluated with Kappa Cohen tests. RESULTS : The results of this study showed high Kappa values regarding the inter-examiner assessment of the impacted canine position with scores ranging from 0.606 - 0.839. The Kappa values determined for resorption, ankylosis and associated lesions were lower with scores between 0.000 and 0.529. CONCLUSION : This study showed that the localization of impacted canines could potentially be possible at low dose (1/4 dose), compared to a conventional assay. However, the diagnosis of resorption, ankylosis or certain associated lesions requires high resolution and therefore full dose acquisitions.

Table of contents

Notes

Notes

Other language versions

Related research dataset(s)

Endorsement

Review

Supplemented By

Referenced By

This document disseminated on Papyrus is the exclusive property of the copyright holders and is protected by the Copyright Act (R.S.C. 1985, c. C-42). Unless the document is published under a Creative Commons licence, it may be used for fair dealing and non-commercial purposes, for private study or research, criticism and review as provided by law. For any other use, written authorization from the copyright holders is required.