Influence of the scleral lens and fluid reservoir thicknesses on residual astigmatism


Article
Version publiée / Version of Record

Date de publication

Identifiant ORCID de l’auteur

Contributrices et contributeurs

Direction de recherche

Publié dans

Journal of contact lens research and science

Date de la Conférence

Lieu de la Conférence

Éditeur

Dougmar Publishing Group

Cycle d'études

Programme

Mots-clés

  • Scleral lenses
  • Residual astigmatism
  • Lens flexure
  • High-order aberrations

Organisme subventionnaire

Résumé

Résumé

Purpose This study aims to determine if lens or tear fluid reservoir thicknesses (LT/FRT) may influence the presence of residual astigmatism and participant’s visual acuity. Methods The study was a randomized, non-dispensing, prospective study. Empirically and randomly chosen participants were fitted with 4 combinations (350 and 250 um LT fitted with 250 and 350 um FRT) of 16 mm diameter scleral lenses, designed using a corneo-scleral profiler software (sMap 3D, Visionary Optics, US). Lenses haptics were kept spherical for all lenses. They were evaluated under a slit lamp, anterior segement OCT (objective fluid reservoir and lens thicknesses), topography over lenses and aberrometry, after 30 minutes of lens wear. Spherico-cylindrical refraction and logMar acuity were also assessed. Results Study population was composed of 24 participants aged 24.2 + 4.7 years old. Baseline refractive error was -2.3 + 1.6 D with -0.48 + 0.26 D of astigmatism. In vivo (OCT) lens A was 344.1 ± 15.4 um thick, fitted with a vault of 213.6 ± 42.4 um; Lens B was 346.2 ± 12.5/327.2 ± 44.8; Lens C was 260.3 ± 17.7/214.0 ± 40.6 um and Lens D was 262.2 ±13.2/330.8 ± 52.0 respectively. All lenses were found similarly decentered inferiorly by 0.10 to 0.15 um. BCVA was −0.32 + 0.08 (A), −0.21 + 0.10 (B), −0.28 + 0.08 (C), and −0.14 + 0.10 (D), compared to −0.25 + 0.08 (A), −0.11 + 0.10 (B), −0.23 + 0.06 (C), and −0.05 + 0.12 (D) when sphere only was compensated. Residual refractive astigmatism (RA = -0.50 to -0.75D) is found significantly higher based on the FRT (F=9.560; p=0.037) and not LT(F=0.429; p=0.522). There is no correlation between RA and over-k readings (Lens A r=-0.078, p=0.773; Lens B r=−0.073, p=0.788; Lens C r=−0.345, p=0.171; Lend D r=0.019, p=0.944). Higher order aberrations, mostly vertical coma, were found clinically significant but not statistically different between lenses (A= 0.350 + 0.032; B=0.382 + 0.053, C=0.329 + 0.044 and D=0.385+ 0.062; p=0.776) Conclusion This study proves that low level of RA may be found when scleral lenses are fitted on normal corneas. Its occurrence is related to the presence of high-order aberrations and less likely to lens flexure.

Table des matières

Notes

Notes

Autre version linguistique

Ensemble de données lié

Licence

: Ce document est mis à disposition selon les termes de la Licence Creative Commons Paternité 4.0 International. / This work is licensed under a Creative Commons Attribution 4.0 International License.

Approbation

Évaluation

Complété par

Référencé par

Ce document diffusé sur Papyrus est la propriété exclusive des titulaires des droits d'auteur et est protégé par la Loi sur le droit d'auteur (L.R.C. (1985), ch. C-42). Sauf si le document est diffusé sous une licence Creative Commons, il ne peut être utilisé que dans le cadre d'une utilisation équitable et non commerciale comme le prévoit la Loi (i.e. à des fins d'étude privée ou de recherche, de critique ou de compte-rendu). Pour toute autre utilisation, une autorisation écrite des titulaires des droits d'auteur sera nécessaire.